authorJan Glauber <jan.glauber@de.ibm.com>2006-02-01 03:06:34 -0800
committerLinus Torvalds <torvalds@g5.osdl.org>2006-02-01 08:53:24 -0800
commit3633b0475eb269dcb85923b23b321505f06b9488 (patch)
tree48e4f85a5f02ba4c56ebc7acbf963372f5f5f573 /drivers/char
parent32f65f274602b43e8f48314e9769f254da1d8323 (diff)
downloadkernel_samsung_smdk4412-3633b0475eb269dcb85923b23b321505f06b9488.zip
kernel_samsung_smdk4412-3633b0475eb269dcb85923b23b321505f06b9488.tar.gz
kernel_samsung_smdk4412-3633b0475eb269dcb85923b23b321505f06b9488.tar.bz2
[PATCH] s390: hangcheck timer support
Remove useless s390 define from hangcheck-timer, remove wrong definition of a TOD second and other s390 ifdefs. Use monotonic_clock instead. Add hangcheck-timer option, copied from drivers/char/Kconfig. This is ugly but unless we have a big Kconfig cleanup we cannot include drivers/char/Kconfig... Signed-off-by: Jan Glauber <jan.glauber@de.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com> Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
Diffstat (limited to 'drivers/char')
-rw-r--r--drivers/char/Kconfig2
-rw-r--r--drivers/char/hangcheck-timer.c12
2 files changed, 2 insertions, 12 deletions
diff --git a/drivers/char/Kconfig b/drivers/char/Kconfig
index 4135d8c..4c67727 100644
--- a/drivers/char/Kconfig
+++ b/drivers/char/Kconfig
@@ -992,7 +992,7 @@ config HPET_MMAP
config HANGCHECK_TIMER
tristate "Hangcheck timer"
- depends on X86 || IA64 || PPC64 || S390
+ depends on X86 || IA64 || PPC64
help
The hangcheck-timer module detects when the system has gone
out to lunch past a certain margin. It can reboot the system
diff --git a/drivers/char/hangcheck-timer.c b/drivers/char/hangcheck-timer.c
index 40a67c8..ac62641 100644
--- a/drivers/char/hangcheck-timer.c
+++ b/drivers/char/hangcheck-timer.c
@@ -117,12 +117,9 @@ __setup("hcheck_reboot", hangcheck_parse_reboot);
__setup("hcheck_dump_tasks", hangcheck_parse_dump_tasks);
#endif /* not MODULE */
-#if defined(CONFIG_X86)
+#if defined(CONFIG_X86) || defined(CONFIG_S390)
# define HAVE_MONOTONIC
# define TIMER_FREQ 1000000000ULL
-#elif defined(CONFIG_S390)
-/* FA240000 is 1 Second in the IBM time universe (Page 4-38 Principles of Op for zSeries */
-# define TIMER_FREQ 0xFA240000ULL
#elif defined(CONFIG_IA64)
# define TIMER_FREQ ((unsigned long long)local_cpu_data->itc_freq)
#elif defined(CONFIG_PPC64)
@@ -134,12 +131,7 @@ extern unsigned long long monotonic_clock(void);
#else
static inline unsigned long long monotonic_clock(void)
{
-# ifdef __s390__
- /* returns the TOD. see 4-38 Principles of Op of zSeries */
- return get_clock();
-# else
return get_cycles();
-# endif /* __s390__ */
}
#endif /* HAVE_MONOTONIC */
@@ -188,8 +180,6 @@ static int __init hangcheck_init(void)
VERSION_STR, hangcheck_tick, hangcheck_margin);
#if defined (HAVE_MONOTONIC)
printk("Hangcheck: Using monotonic_clock().\n");
-#elif defined(__s390__)
- printk("Hangcheck: Using TOD.\n");
#else
printk("Hangcheck: Using get_cycles().\n");
#endif /* HAVE_MONOTONIC */