aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/net/bnx2.h
diff options
context:
space:
mode:
authorMichael Chan <mchan@broadcom.com>2008-11-12 16:02:20 -0800
committerDavid S. Miller <davem@davemloft.net>2008-11-12 16:02:20 -0800
commitd8026d939495c105cf747c0196a8fa738cf2ad20 (patch)
tree9240f3af1002c84bfdedbc4c952234684eef3a92 /drivers/net/bnx2.h
parent5ec6d7bf195c2e70003ff30e4f51390ef7e85a31 (diff)
downloadkernel_samsung_smdk4412-d8026d939495c105cf747c0196a8fa738cf2ad20.zip
kernel_samsung_smdk4412-d8026d939495c105cf747c0196a8fa738cf2ad20.tar.gz
kernel_samsung_smdk4412-d8026d939495c105cf747c0196a8fa738cf2ad20.tar.bz2
bnx2: Set rx buffer water marks based on MTU.
The default rx buffer water marks for XOFF/XON are for 1500 MTU. At larger MTUs, these water marks need to be adjusted for effective flow control. Signed-off-by: Michael Chan <mchan@broadcom.com> Signed-off-by: Matt Carlson <mcarlson@broadcom.com> Signed-off-by: Benjamin Li <benli@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/bnx2.h')
-rw-r--r--drivers/net/bnx2.h21
1 files changed, 21 insertions, 0 deletions
diff --git a/drivers/net/bnx2.h b/drivers/net/bnx2.h
index 617d953..2b9649ae 100644
--- a/drivers/net/bnx2.h
+++ b/drivers/net/bnx2.h
@@ -4199,7 +4199,14 @@ struct l2_fhdr {
#define BNX2_RBUF_CONFIG 0x0020000c
#define BNX2_RBUF_CONFIG_XOFF_TRIP (0x3ffL<<0)
+#define BNX2_RBUF_CONFIG_XOFF_TRIP_VAL(mtu) \
+ ((((mtu) - 1500) * 31 / 1000) + 54)
#define BNX2_RBUF_CONFIG_XON_TRIP (0x3ffL<<16)
+#define BNX2_RBUF_CONFIG_XON_TRIP_VAL(mtu) \
+ ((((mtu) - 1500) * 39 / 1000) + 66)
+#define BNX2_RBUF_CONFIG_VAL(mtu) \
+ (BNX2_RBUF_CONFIG_XOFF_TRIP_VAL(mtu) | \
+ (BNX2_RBUF_CONFIG_XON_TRIP_VAL(mtu) << 16))
#define BNX2_RBUF_FW_BUF_ALLOC 0x00200010
#define BNX2_RBUF_FW_BUF_ALLOC_VALUE (0x1ffL<<7)
@@ -4221,11 +4228,25 @@ struct l2_fhdr {
#define BNX2_RBUF_CONFIG2 0x0020001c
#define BNX2_RBUF_CONFIG2_MAC_DROP_TRIP (0x3ffL<<0)
+#define BNX2_RBUF_CONFIG2_MAC_DROP_TRIP_VAL(mtu) \
+ ((((mtu) - 1500) * 4 / 1000) + 5)
#define BNX2_RBUF_CONFIG2_MAC_KEEP_TRIP (0x3ffL<<16)
+#define BNX2_RBUF_CONFIG2_MAC_KEEP_TRIP_VAL(mtu) \
+ ((((mtu) - 1500) * 2 / 100) + 30)
+#define BNX2_RBUF_CONFIG2_VAL(mtu) \
+ (BNX2_RBUF_CONFIG2_MAC_DROP_TRIP_VAL(mtu) | \
+ (BNX2_RBUF_CONFIG2_MAC_KEEP_TRIP_VAL(mtu) << 16))
#define BNX2_RBUF_CONFIG3 0x00200020
#define BNX2_RBUF_CONFIG3_CU_DROP_TRIP (0x3ffL<<0)
+#define BNX2_RBUF_CONFIG3_CU_DROP_TRIP_VAL(mtu) \
+ ((((mtu) - 1500) * 12 / 1000) + 18)
#define BNX2_RBUF_CONFIG3_CU_KEEP_TRIP (0x3ffL<<16)
+#define BNX2_RBUF_CONFIG3_CU_KEEP_TRIP_VAL(mtu) \
+ ((((mtu) - 1500) * 2 / 100) + 30)
+#define BNX2_RBUF_CONFIG3_VAL(mtu) \
+ (BNX2_RBUF_CONFIG3_CU_DROP_TRIP_VAL(mtu) | \
+ (BNX2_RBUF_CONFIG3_CU_KEEP_TRIP_VAL(mtu) << 16))
#define BNX2_RBUF_PKT_DATA 0x00208000
#define BNX2_RBUF_CLIST_DATA 0x00210000