aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/net/bnx2x
diff options
context:
space:
mode:
authorVladislav Zolotarov <vladz@broadcom.com>2011-05-04 23:48:23 +0000
committerDavid S. Miller <davem@davemloft.net>2011-05-05 10:44:33 -0700
commit2ae17f666099c952053eea7c64cac8189dd76f72 (patch)
tree69da6881c755adccec1ef4e09ec28bc499e979e9 /drivers/net/bnx2x
parent34da9e50e908c4553ddefb38da2c5bacbe2bba58 (diff)
downloadkernel_samsung_smdk4412-2ae17f666099c952053eea7c64cac8189dd76f72.zip
kernel_samsung_smdk4412-2ae17f666099c952053eea7c64cac8189dd76f72.tar.gz
kernel_samsung_smdk4412-2ae17f666099c952053eea7c64cac8189dd76f72.tar.bz2
bnx2x: link report improvements
To avoid link notification duplication Signed-off-by: Dmitry Kravkov <dmitry@broadcom.com> Signed-off-by: Vladislav Zolotarov <vladz@broadcom.com> Signed-off-by: Eilon Greenstein <eilong@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/bnx2x')
-rw-r--r--drivers/net/bnx2x/bnx2x.h21
-rw-r--r--drivers/net/bnx2x/bnx2x_cmn.c129
-rw-r--r--drivers/net/bnx2x/bnx2x_cmn.h5
-rw-r--r--drivers/net/bnx2x/bnx2x_main.c21
4 files changed, 141 insertions, 35 deletions
diff --git a/drivers/net/bnx2x/bnx2x.h b/drivers/net/bnx2x/bnx2x.h
index 9e87417..1a005a4 100644
--- a/drivers/net/bnx2x/bnx2x.h
+++ b/drivers/net/bnx2x/bnx2x.h
@@ -893,6 +893,22 @@ typedef enum {
(&bp->def_status_blk->sp_sb.\
index_values[HC_SP_INDEX_EQ_CONS])
+/* This is a data that will be used to create a link report message.
+ * We will keep the data used for the last link report in order
+ * to prevent reporting the same link parameters twice.
+ */
+struct bnx2x_link_report_data {
+ u16 line_speed; /* Effective line speed */
+ unsigned long link_report_flags;/* BNX2X_LINK_REPORT_XXX flags */
+};
+
+enum {
+ BNX2X_LINK_REPORT_FD, /* Full DUPLEX */
+ BNX2X_LINK_REPORT_LINK_DOWN,
+ BNX2X_LINK_REPORT_RX_FC_ON,
+ BNX2X_LINK_REPORT_TX_FC_ON,
+};
+
struct bnx2x {
/* Fields used in the tx and intr/napi performance paths
* are grouped together in the beginning of the structure
@@ -1025,6 +1041,9 @@ struct bnx2x {
struct link_params link_params;
struct link_vars link_vars;
+ u32 link_cnt;
+ struct bnx2x_link_report_data last_reported_link;
+
struct mdio_if_info mdio;
struct bnx2x_common common;
@@ -1441,6 +1460,8 @@ struct bnx2x_func_init_params {
#define WAIT_RAMROD_POLL 0x01
#define WAIT_RAMROD_COMMON 0x02
+void bnx2x_read_mf_cfg(struct bnx2x *bp);
+
/* dmae */
void bnx2x_read_dmae(struct bnx2x *bp, u32 src_addr, u32 len32);
void bnx2x_write_dmae(struct bnx2x *bp, dma_addr_t dma_addr, u32 dst_addr,
diff --git a/drivers/net/bnx2x/bnx2x_cmn.c b/drivers/net/bnx2x/bnx2x_cmn.c
index 8729061..8853ae2 100644
--- a/drivers/net/bnx2x/bnx2x_cmn.c
+++ b/drivers/net/bnx2x/bnx2x_cmn.c
@@ -758,35 +758,119 @@ u16 bnx2x_get_mf_speed(struct bnx2x *bp)
return line_speed;
}
+/**
+ * bnx2x_fill_report_data - fill link report data to report
+ *
+ * @bp: driver handle
+ * @data: link state to update
+ *
+ * It uses a none-atomic bit operations because is called under the mutex.
+ */
+static inline void bnx2x_fill_report_data(struct bnx2x *bp,
+ struct bnx2x_link_report_data *data)
+{
+ u16 line_speed = bnx2x_get_mf_speed(bp);
+
+ memset(data, 0, sizeof(*data));
+
+ /* Fill the report data: efective line speed */
+ data->line_speed = line_speed;
+
+ /* Link is down */
+ if (!bp->link_vars.link_up || (bp->flags & MF_FUNC_DIS))
+ __set_bit(BNX2X_LINK_REPORT_LINK_DOWN,
+ &data->link_report_flags);
+
+ /* Full DUPLEX */
+ if (bp->link_vars.duplex == DUPLEX_FULL)
+ __set_bit(BNX2X_LINK_REPORT_FD, &data->link_report_flags);
+
+ /* Rx Flow Control is ON */
+ if (bp->link_vars.flow_ctrl & BNX2X_FLOW_CTRL_RX)
+ __set_bit(BNX2X_LINK_REPORT_RX_FC_ON, &data->link_report_flags);
+
+ /* Tx Flow Control is ON */
+ if (bp->link_vars.flow_ctrl & BNX2X_FLOW_CTRL_TX)
+ __set_bit(BNX2X_LINK_REPORT_TX_FC_ON, &data->link_report_flags);
+}
+
+/**
+ * bnx2x_link_report - report link status to OS.
+ *
+ * @bp: driver handle
+ *
+ * Calls the __bnx2x_link_report() under the same locking scheme
+ * as a link/PHY state managing code to ensure a consistent link
+ * reporting.
+ */
+
void bnx2x_link_report(struct bnx2x *bp)
{
- if (bp->flags & MF_FUNC_DIS) {
- netif_carrier_off(bp->dev);
- netdev_err(bp->dev, "NIC Link is Down\n");
- return;
- }
+ bnx2x_acquire_phy_lock(bp);
+ __bnx2x_link_report(bp);
+ bnx2x_release_phy_lock(bp);
+}
- if (bp->link_vars.link_up) {
- u16 line_speed;
+/**
+ * __bnx2x_link_report - report link status to OS.
+ *
+ * @bp: driver handle
+ *
+ * None atomic inmlementation.
+ * Should be called under the phy_lock.
+ */
+void __bnx2x_link_report(struct bnx2x *bp)
+{
+ struct bnx2x_link_report_data cur_data;
- if (bp->state == BNX2X_STATE_OPEN)
- netif_carrier_on(bp->dev);
- netdev_info(bp->dev, "NIC Link is Up, ");
+ /* reread mf_cfg */
+ if (!CHIP_IS_E1(bp))
+ bnx2x_read_mf_cfg(bp);
+
+ /* Read the current link report info */
+ bnx2x_fill_report_data(bp, &cur_data);
+
+ /* Don't report link down or exactly the same link status twice */
+ if (!memcmp(&cur_data, &bp->last_reported_link, sizeof(cur_data)) ||
+ (test_bit(BNX2X_LINK_REPORT_LINK_DOWN,
+ &bp->last_reported_link.link_report_flags) &&
+ test_bit(BNX2X_LINK_REPORT_LINK_DOWN,
+ &cur_data.link_report_flags)))
+ return;
+
+ bp->link_cnt++;
- line_speed = bnx2x_get_mf_speed(bp);
+ /* We are going to report a new link parameters now -
+ * remember the current data for the next time.
+ */
+ memcpy(&bp->last_reported_link, &cur_data, sizeof(cur_data));
- pr_cont("%d Mbps ", line_speed);
+ if (test_bit(BNX2X_LINK_REPORT_LINK_DOWN,
+ &cur_data.link_report_flags)) {
+ netif_carrier_off(bp->dev);
+ netdev_err(bp->dev, "NIC Link is Down\n");
+ return;
+ } else {
+ netif_carrier_on(bp->dev);
+ netdev_info(bp->dev, "NIC Link is Up, ");
+ pr_cont("%d Mbps ", cur_data.line_speed);
- if (bp->link_vars.duplex == DUPLEX_FULL)
+ if (test_and_clear_bit(BNX2X_LINK_REPORT_FD,
+ &cur_data.link_report_flags))
pr_cont("full duplex");
else
pr_cont("half duplex");
- if (bp->link_vars.flow_ctrl != BNX2X_FLOW_CTRL_NONE) {
- if (bp->link_vars.flow_ctrl & BNX2X_FLOW_CTRL_RX) {
+ /* Handle the FC at the end so that only these flags would be
+ * possibly set. This way we may easily check if there is no FC
+ * enabled.
+ */
+ if (cur_data.link_report_flags) {
+ if (test_bit(BNX2X_LINK_REPORT_RX_FC_ON,
+ &cur_data.link_report_flags)) {
pr_cont(", receive ");
- if (bp->link_vars.flow_ctrl &
- BNX2X_FLOW_CTRL_TX)
+ if (test_bit(BNX2X_LINK_REPORT_TX_FC_ON,
+ &cur_data.link_report_flags))
pr_cont("& transmit ");
} else {
pr_cont(", transmit ");
@@ -794,10 +878,6 @@ void bnx2x_link_report(struct bnx2x *bp)
pr_cont("flow control ON");
}
pr_cont("\n");
-
- } else { /* link_down */
- netif_carrier_off(bp->dev);
- netdev_err(bp->dev, "NIC Link is Down\n");
}
}
@@ -1345,6 +1425,13 @@ int bnx2x_nic_load(struct bnx2x *bp, int load_mode)
bp->state = BNX2X_STATE_OPENING_WAIT4_LOAD;
+ /* Set the initial link reported state to link down */
+ bnx2x_acquire_phy_lock(bp);
+ memset(&bp->last_reported_link, 0, sizeof(bp->last_reported_link));
+ __set_bit(BNX2X_LINK_REPORT_LINK_DOWN,
+ &bp->last_reported_link.link_report_flags);
+ bnx2x_release_phy_lock(bp);
+
/* must be called before memory allocation and HW init */
bnx2x_ilt_set_info(bp);
diff --git a/drivers/net/bnx2x/bnx2x_cmn.h b/drivers/net/bnx2x/bnx2x_cmn.h
index 1cdab69..007f294 100644
--- a/drivers/net/bnx2x/bnx2x_cmn.h
+++ b/drivers/net/bnx2x/bnx2x_cmn.h
@@ -67,11 +67,12 @@ void bnx2x__link_status_update(struct bnx2x *bp);
* Report link status to upper layer
*
* @param bp
- *
- * @return int
*/
void bnx2x_link_report(struct bnx2x *bp);
+/* None-atomic version of bnx2x_link_report() */
+void __bnx2x_link_report(struct bnx2x *bp);
+
/**
* calculates MF speed according to current linespeed and MF
* configuration
diff --git a/drivers/net/bnx2x/bnx2x_main.c b/drivers/net/bnx2x/bnx2x_main.c
index bfd7ac9..3f4ff41 100644
--- a/drivers/net/bnx2x/bnx2x_main.c
+++ b/drivers/net/bnx2x/bnx2x_main.c
@@ -2036,7 +2036,7 @@ static int bnx2x_get_cmng_fns_mode(struct bnx2x *bp)
return CMNG_FNS_NONE;
}
-static void bnx2x_read_mf_cfg(struct bnx2x *bp)
+void bnx2x_read_mf_cfg(struct bnx2x *bp)
{
int vn, n = (CHIP_MODE_IS_4_PORT(bp) ? 2 : 1);
@@ -2123,7 +2123,6 @@ static inline void bnx2x_link_sync_notify(struct bnx2x *bp)
/* This function is called upon link interrupt */
static void bnx2x_link_attn(struct bnx2x *bp)
{
- u32 prev_link_status = bp->link_vars.link_status;
/* Make sure that we are synced with the current statistics */
bnx2x_stats_handle(bp, STATS_EVENT_STOP);
@@ -2168,17 +2167,15 @@ static void bnx2x_link_attn(struct bnx2x *bp)
"single function mode without fairness\n");
}
+ __bnx2x_link_report(bp);
+
if (IS_MF(bp))
bnx2x_link_sync_notify(bp);
-
- /* indicate link status only if link status actually changed */
- if (prev_link_status != bp->link_vars.link_status)
- bnx2x_link_report(bp);
}
void bnx2x__link_status_update(struct bnx2x *bp)
{
- if ((bp->state != BNX2X_STATE_OPEN) || (bp->flags & MF_FUNC_DIS))
+ if (bp->state != BNX2X_STATE_OPEN)
return;
bnx2x_link_status_update(&bp->link_params, &bp->link_vars);
@@ -2188,10 +2185,6 @@ void bnx2x__link_status_update(struct bnx2x *bp)
else
bnx2x_stats_handle(bp, STATS_EVENT_STOP);
- /* the link status update could be the result of a DCC event
- hence re-read the shmem mf configuration */
- bnx2x_read_mf_cfg(bp);
-
/* indicate link status */
bnx2x_link_report(bp);
}
@@ -3120,10 +3113,14 @@ static inline void bnx2x_attn_int_deasserted3(struct bnx2x *bp, u32 attn)
if (val & DRV_STATUS_SET_MF_BW)
bnx2x_set_mf_bw(bp);
- bnx2x__link_status_update(bp);
if ((bp->port.pmf == 0) && (val & DRV_STATUS_PMF))
bnx2x_pmf_update(bp);
+ /* Always call it here: bnx2x_link_report() will
+ * prevent the link indication duplication.
+ */
+ bnx2x__link_status_update(bp);
+
if (bp->port.pmf &&
(val & DRV_STATUS_DCBX_NEGOTIATION_RESULTS) &&
bp->dcbx_enabled > 0)