From 4faf4e0e7d4e1935fbfc5043d3ebd8d51a3d898d Mon Sep 17 00:00:00 2001 From: Lennert Buytenhek Date: Tue, 20 Jun 2006 19:24:07 +0100 Subject: [ARM] 3600/1: increase amba-pl010 UART_NR to 8 Patch from Lennert Buytenhek The cirrus ep93xx has 3 pl010 UARTs, while amba-pl010.c only allows for 2 by default. A while ago, I think we agreed on changing the 2 to 8, but I don't see this in 2.6.17 yet. Signed-off-by: Lennert Buytenhek Signed-off-by: Russell King --- drivers/serial/amba-pl010.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) (limited to 'drivers/serial/amba-pl010.c') diff --git a/drivers/serial/amba-pl010.c b/drivers/serial/amba-pl010.c index 1631414..e920d19 100644 --- a/drivers/serial/amba-pl010.c +++ b/drivers/serial/amba-pl010.c @@ -52,7 +52,7 @@ #include -#define UART_NR 2 +#define UART_NR 8 #define SERIAL_AMBA_MAJOR 204 #define SERIAL_AMBA_MINOR 16 -- cgit v1.1